Solid-State Bipolar Marx Generator with Voltage Droop Compensation - Technological Innovation for Value Creation
Conference Papers Year : 2012

Solid-State Bipolar Marx Generator with Voltage Droop Compensation

Abstract

This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.
Fichier principal
Vignette du fichier
978-3-642-28255-3_45_Chapter.pdf (264.18 Ko) Télécharger le fichier
Origin Files produced by the author(s)
Loading...

Dates and versions

hal-01365752 , version 1 (13-09-2016)

Licence

Identifiers

Cite

H. Canacsinh, José Fernando Silva, Sónia F. Pinto, Luis M. Redondo. Solid-State Bipolar Marx Generator with Voltage Droop Compensation. 3rd Doctoral Conference on Computing, Electrical and Industrial Systems (DoCEIS), Feb 2012, Costa de Caparica, Portugal. pp.411-418, ⟨10.1007/978-3-642-28255-3_45⟩. ⟨hal-01365752⟩
95 View
511 Download

Altmetric

Share

More